Scanpro3-200 Mycobacterium Tuberculosis Microscopy Scanning System

The Scanpro3-200 Mycobacterium Tuberculosis Microscopy Scanning System uses high-precision digital microscopy system to automatically acquire and preserve sputum smear image acquisition, intelligent recognition analysis and processing the image, combined with advanced artificial intelligence algorithm, the equipment give negative and positive grade to determine the sputum smear.


Product Detail

Download

Quality Control

Product Tags

Scanpro3-200 Mycobacterium Tuberculosis Microscopy Scanning System

 Scanpro3-200

Introduction

Mycobacterium tuberculosis (M. tuberculosis), commonly known as tuberculosis, is the pathogen causing tuberculosis. Can invade all organs of the body, but the tuberculosis is the most common. Tuberculosis is still an important infectious disease. According to WHO statistics, about one out of every three people in the world is infected with Mycobacterium tuberculosis.

At present, the checkup of tuberculosis by medical institutions mainly depends on the traditional microscope, and using manual sputum smear. The traditional microscope is still facing following issues: Low efficiency, high undetected rate, big difference in diagnosis, difficult referral, sharing data cannot be saved, high work intensity and many other defects. Manual sputum smear microscopy inspection mode needs to be gradually replaced by automated equipment.

Scanpro3-200 Mycobacterium Tuberculosis Microscopy Scanning System uses high-precision digital microscopy system to automatically acquire and preserve sputum smear image acquisition, intelligent recognition analysis and processing the image, combined with advanced artificial intelligence algorithm, the equipment give negative and positive grade to determine the sputum smear. Microscopy for Mycobacterium tuberculosis can be used for Ziehl-Neelsen acid-fast (antacid), auramine O staining (fluorescence).

Feature

1.Newly designed optical component system

A newly designed optical component system for automatic scanning of Mycobacterium tuberculosis, not a microscope modified system. Using custom optics scanning, the equivalent of 100 times the lens of the manual microscopy to 1600 standard field of view, the observation area covers the standard sputum area of 32%. The lens does not require refueling, do not need daily cleaning Maintenance, long lens life.

 

2.Smart scanning

Fully intelligent continuous scanning, one-click operation, 24 hours unattended, greatly improving work efficiency, and automatically cutting off power after scanning.

 

3.High-flux scanning

Supporting up to 200/50 sheets of smear at once, each fine scanning takes only about 3 minutes, and digital images can be permanently saved. During normal operation, the system automatically completes the loading and retrieval of smears. Supporting the urgent scanning of temporary smears. Supporting simultaneous scanning and reading of smear. Scan results can be customized for retrieval, statistics, etc.

 

4.Simple operation

Just put the processed smear into the system slide box at once, click "Start" in the computer. The Process can be stopped at any time with one key and emergency smears can be ready for insertion.

 

5.Intelligent identification

Powerful intelligent identification and analysis software, automatically identifies Mycobacterium tuberculosis, forms auxiliary diagnostic recommendations, and can customize bacterial model libraries according to different hospitals.

 

6.Information sharing

It can achieve information sharing with hospital information systems, as well as between doctors and patients. The smears can be viewed and discussed remotely via the Internet or local LAN, so that cross hospital diagnostic communication is no longer a problem.

 

7.System work flow

Process: Automatically scan images and digitally save. Image intelligent set up and analyze. Sputum smear negative / positive grade recommendations are automatically given. Auxiliary diagnosis.

Functions: Scan results pre-screening function. Urgent slice scan check function. Scan results custom statistics function. Binocular microscope inspection function. Target positioning / visual auto function.

 

Ziehl-Neelsen Acid-fast Staining

2-7-1 Zihel-Neelsen Acid-fast Stanning-Scanning Interface

Scanning interface

 

Scanpro3 Zihel-Neelsen Acid-fast Staning-Intelligent Identification

Intelligent identification

 

Scanpro3 Zihel-Neelsen Acid-fast Staning-Diagnostic Report

Diagnostic report

 

Auramine O staining

Scanpro3 Auramine O Staning-Scanning Interface

Scanning interface

Scanpro3 Auramine O Staning-Intelligent Identification

Intelligent identification

Scanpro3 Auramine O Staning-Intelligent Identification

Diagnostic report

Specification

Item Specification Scanpro 3-50 Scanpro 3-200 Scanpro 3-50FL Scanpro 3-200FL
Scanning Optical System A newly designed optical component system specifically designed for automatic scanning of Mycobacterium tuberculosis, without the need for refueling during scanning
A newly designed professional fluorescence optical component system specifically designed for automatic scanning of Mycobacterium tuberculosis
Manual Review Device Built-in integrated manual assisted lens inspection and review device, equipped with high eyepoint wide field eyepieces
Illumination System Professional LED illumination system for microscopic observation, long lifespan, no flicker, energy-saving and environmental-friendly
Maximum Loading Capacity 50 slices
200 slices
Integrated slide box, supporting single slide urgent scanning, supporting scanning, loading, and reading at the same time
Scanning motion mechanism The fast focusing mechanism with linear motor and magnetic levitation has good stability, low mechanical wear and long life
Objective Infinity Plan Apochromatic Objective 20X, NA 0.5, WD=2.0mm
Infinity Plan Apochromatic Objective 40X, NA 0.75, WD=0.74mm
Infinity Plan Apochromatic Objective 60X, NA 0.9, WD=0.26mm
Camera Professional camera with ultra-high resolution, 7 mega-pixels, 3200*2200, target size: 1.1”
Professional camera with ultra-high resolution, 4 mega-pixels, 2048*2048, target size: 1”
Professional fluorescent camera with high brightness and ultra-high resolution, 4 mega-pixels, 2048*2048, target size: 2/3”
Label Recognition Panoramic camera, supporting automatic recognition of the entire slides and its label
Scanning Time 1-4 minutes for each slice, depending on the scanning area and smear quality
Electrical Equipment Requirements Meeting medical device requirements
Others Supporting depth of field extension, multi-layer scanning, coating area recognition, automatic/manual control of scanning area and scanning position, etc.
Slide Loading Type 66cm(L)*50cm(W)*67cm(H)
86.5cm(L)*67cm(W)*71.4cm(H)
66cm(L)*50cm(W)*67cm(H)
86.5cm(L)*67cm(W)*71.4cm(H)

cNote: ● Standard Outfit, ○ Optional

Certificate

mhg

Logistics

pic (3)

  • Previous:
  • Next:

  • Scanpro3 Series Mycobacterium Tuberculosis Microscopy Scanning System

    pic (1) pic (2)