BSM Digital Microscanner

The BSM Digital Microscanner is an organic combination of modern digital systems and traditional optical magnification devices. After digital imaging of specimens through this technology, researchers can perform digital reading at any location, realizing a revolution in digital imaging and reading.


Product Detail

Download

Quality Control

Product Tags

BSM Microscanner

 BSM

Introduction

In the research process of life science, microscopic observation is an indispensable technique. But traditional microscopic observation is limited by time, region, personnel and equipment. Specimens must be observed in the laboratory by professionals using a microscope device. The Whole Slide Imaging (WSI) technology is an organic combination of modern digital systems and traditional optical magnification devices. After digital imaging of specimens through this technology, researches can perform digital reading at any location, realizing a revolution in digital imaging and reading.

Feature

1.Bright field & fluorescence imaging methods

The product has both bright field and fluorescence imaging methods, allowing researchers to switch freely in and application.

BSM Bright Field & Fluorescence Imaging Method

 

2.Support standard slides and various custom size slides

BSM Support Standard Slides and Various Custom Size Slides-1
BSM Support Standard Slides and Various Custom Size Slides-2
BSM Support Standard Slides and Various Custom Size Slides-3

 

3.Multi objective lens system

BSM series support configuration of multiple objective lenses, up to 3. It is convenient for researchers to observe specimens from low magnification to high magnification, or even oil lens, supporting various application scenarios and projects.

BSM Multi Objective Lens System

 

 

BSM APO objective

 

4.Automatic oil filling

The automatic oil dripping system can meet the needs of researchers for oil lens observation. The automatic oil dripping system eliminates the trouble of researchers frequently oiling the objective lens.

BSM Automatic Oil Filling

 

5.Multi feeding mechanism

The feeding mechanism is designed to be 5 pieces, 50 pieces, 100 pieces, 200 pieces, (it can be customized to upgrade to 400 pieces, 600 pieces, of higher throughput).

Each tray can hold up to 5 standard slides, and the tray-type design ensures the safety of specimens, without broke or stuck. The label recognition of slide specimens can be realized before the specimen is scanned, and barcode/QR code is supported. Panoramic image acquisition and algorithms before scanning can help researchers locate the scanning area more quickly, or manually set scanning parameters to meet individual needs.

BSM Multiple Feeding Mechanism

 

6.Efficient and user-friendly operation

BSM Efficient and User-friendly Operation-1
BSM Efficient and User-friendly Operation-2

 

The operation interface and image reading and observation interface are simple and easy to use. The concise working interface provides the greatest convenience for researchers. Digital slice reading software (local/remote).

 

BSM Efficient and User-friendly Operation-3
BSM Efficient and User-friendly Operation-4

 

The software can be accessed through local or network storage to view microscopic digital slices, and can also view uploaded microscopic digital slice images through internet connection or local area network connection. Support image annotation, measurement and other functions.

Specification

Item Specification BSM
Observable Sample Slides with/without standard coverslips
Slide Size Standard slide trays (L*W*H, 5 slides): 75mm-76.5mm (2.95in-3in), 25mm-26.5mm (0.98in-1in), 0.9mm-1.2mm (0.04in inches-0.05 inches)
Optional slide tray 1 (L*W*H, 2 slides): 75mm-76.5mm (2.95in-3in), 51mm to 53mm (2 in-2.09in), 0.9mm-1.2mm (0.04 inches-0.05 inches)
Optional slide tray 2 (L*W*H, 1 slide): 100mm-102mm (3.94in-4.02in), 75mm-76.5mm (2.95in-3in), 0.9-1.2mm (0.04 inches-0.05 inches)
Observation Method Bright field
Fluorescence
Illuminator Built-in transmitted light Kohler illumination, high intensity and high color rendering LED (up to 50,000 hours lifetime)
Objective Lens Compatible objectives: 10X, 20X, 40X, 60X and 100X. 3-position motorized turret (includes select oil immersion)
Automatic oil distributor
Stage Automatically controlled motorized XY stage
Focusing Automatically controlled autofocus with support for focused topographic maps and real-time autofocus
Scan Camera Color camera, 1.1” CMOS, 4.5um*4.5um pixels, 7 mega-pixels, high sensitivity, high resolution
Monochrome camera, 1.1” CMOS, 4.5um*4.5um pixels, 7 mega-pixels, high sensitivity, high resolution
Panoramic Camera Color Camera, 5 mega-pixels
Capacity 5 slides: 1 slide tray, up to 5 slides, can be upgraded to multi-tray feeding mechanism
100/200 slides: up to 40 slides trays, up to 200 slides
400/600 pieces can be customized
Pixel Resolution 10X (NA 0.4):20X (NA 0.8): 0.335um/pixel

40X (NA 0.95): 0.168um/pixel

60X (NA 1.4): 0.112um/pixel

100X (NA 1.35): 0.067um/pixel

Scanning Time Bright field is less than 60 seconds (20X objective lens, scanning area 15mm*15mm)
Software Auto barcode reading, auto focus topographic map, auto scan, auto stitching, pause and resume scanning, Z-stack imaging, multiple image formats (BMP, JPEG and TIFF), simultaneous multi-image display, stepless zoom, upload while scanning slide browsing, annotation, screen capture
Fluorescence Equipped with professional LED fluorescent illuminator, motorized 4-hole fluorescent reflected lens turntable, motorized filter wheel, fluorescent light source
Oil component Long life, maintenance-free, 5 million times
Weight Microscanner of 5 slides: 40kg, microscanner of 200 slides: 70kg. 1 slide tray: 0.1 kg
Operating Environment Temperature: 10°C-30°C. Humidity: up to 80% (non-condensing)
Power Consumption 220W
Power Rating Input: 220V AC, 50Hz, 1A

Note: ● Standard Outfit, ○ Optional

Application

Microorganism

Microbial smears are commonly used for clinical inspection, teaching and scientific research. Microorganisms are analyzed by observing the microstructure, quantity and dynamics of microorganisms such as bacteria and fungi. The BSM microscanner can convert microbial smear specimens into digital slides, enabling digital reading at multiple terminals.

 

BSM Gram-negative Bacteria Escherichia Coli

Gram-negative bacteria Escherichia coli

BSM Nissl Staining

Nissl staining

BSM Auramine Ostaining

Auramine O staining

Pathology

In histopathological and cytopathological studies, the ability to assess cell morphology and analyze two objects (localization) in close proximity or overlapping with each other is critical. Based on the accumulation of optical technology for many years, the optical system of BSM microscanner can make the target cells clearer. The cells and tissues can be seen at a glance, and the pathological section can be comprehensively evaluated.

 

BSM Pathology
BSM Pathology

FISH fluorescence

Immunofluorescence technology is often used in disease diagnosis and drug development to analyze samples. BSM microscanner can detect multiple molecular targets in samples, gathering information from multiple molecular targets onto a digital slide through image fusion. It provides a powerful help for the researchers to analyze the results.

 

BSM Multicolor Fluorescence Fusion Image

Multicolor fluorescence fusion image

Blood

Blood is one of the most important tissues in the human body. The changes of white blood cells, platelets and red blood cells in the blood reflect the health and metabolic level of the human body. In clinical inspection work, blood cell morphological examination is a basic but very important inspection item. BSM microscanner can convert blood cell smears into digital slides, and provide high-definition and comprehensive blood cell images for inspection personnel on the reading software for diagnosis.

 

BSM Blood Cell Morphology Analysis

Blood cell morphology analysis

Sample Image

BSM Immunofluorescence Slide

Immunofluorescence slide

BSM Plant Slide

Plant slide

BSM Tissue Sections Slide

Tissue sections slide

BSM Chromosome Karyotype Slide

Chromosome karyotype slide

Certificate

mhg

Logistics

pic (3)

  • Previous:
  • Next:

  • BSM Slide Scanner

    pic (1) pic (2)